Accurate distal access and high flow
Terumo presents a technological breakthrough: the Progreat microcatheter system designed towards controlled, precise and selective therapeutic embolization and angiography in peripheral vessels.
Characteristics
Quick

  • Tungsten spiral coil
    The tungsten coil protects inner lumen integrity and provides excellent kink resistance, allowing smooth delivery of all types of embolic materials. It also allows large inner lumen to achieve optimal flow rate with high pressure (Max. 900 psi/ 6.205 kPa)(1)
  • Varied outer layer
    The varied materials of the outer layer provide stiffness for transition towards the distal tip of the microcatheter, ensuring reliable trackability into narrow and tortuous target vessels(1)
  • Fast flushing (coaxial type)
    Prime at least 1mL of heparinised saline solution through the coaxial wire port. Allow more than 10 drops to exit from the microcatheter tip. This activates the coaxial wire’s hydrophilic coating and lubricates the inner lumen of the Progreat

Slick

  • PTFE inner layer
    The smooth PTFE surface provides virtually frictionless passage for exceptional precision in guidewire control and embolic agent delivery
  • M Coat™
    Terumo’s famous hydrophilic coating facilitates navigation through vascular anatomy, helping to make Progreat a breakthrough in conventional angiographic practice
  • Three-layer structure
    This original structure not only provides Progreat with its world-renowned resistance to kinking, but also enhances its radiopacity and distal flexibility for a more precise catheter placement(1)

Accurate

  • Varied coil pitch
    The varied pitch of the tungsten coil provides microcatheter tip flexibility thus notably increasing its distal selectivity in tortuous and narrow vessels towards distal lesions(1)
  • Optimal visibility
    For rapid and precise positioning, Progreat is available with three radiopaque components. The structure of the catheter itself is a radiopaque tungsten coil. A specific 0.7 mm platinum/iridium marker indicates the distal end. In the coaxial version, Progreat is delivered with a Radifocus Guidewire GT including a 3 cm gold coil at tip.
  • Wire stopper
    This device allows variable protruding length of guidewire and provides a perfect control of stability and accessibility to the targeted lesion.

(1) Bench testing done by Terumo Corporation. Data on file (TC-Pro107). Bench test data may not necessarily indicative of clinical performance.